Hanna pH Electrode with Clogging Prevention System (CPS™) and BNC Connector (0.5m Cable) (Replacement electrode for HI84502-01) (Hanna# HI1048B/50)

    • Low stock!

    Description

    The HI1048B is a glass body, refillable, sleeve junction pH electrode with a BNC connector. This electrode features a double junction reference, Hanna's Clogging Prevention System (CPS) technology and spherical glass sensing bulb made with general purpose glass. This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode.
    • Clogging Prevention System (CPS™) Technology
    • Refillable Electrode
    • Double Junction Design
    Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.
     
    The HI1048B uses general purpose (GP) glass, spherical bulb, glass body, sleeve junction with CPS™ technology, double junction and is refillable with 3.5M KCl, making it ideal for wine must, juice, and other samples with a high solids content.
     
    General Purpose Glass Formulation
    General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25°C and is suited for measuring the pH of samples that are at ambient temperatures. The HI1048B is suitable to use with samples that measure from 0 to 80°C.
     
    Spherical Glass Tip
    The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability.
     
    CPS Sleeve Junction
    Clogging Prevention System (CPS) technology is an innovation in for the improvement of pH measurements in samples that have a high solids content. Conventional pH electrodes use ceramic junctions that can clog quickly when used in samples that have a high solids content such as wine must or juice. When the junction is clogged, the electrode does not function. CPS technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows the proper flow of the liquid, while the PTFE sleeve repels solids. As a result, pH electrodes with CPS technology take up to 20 times longer to be fouled as compared to conventional electrodes.
     
    Double Junction Reference
    A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or for samples that contain sulfides that can cause the silver to precipitates and clog the junction. The clogging of the junction will result in drifty and erratic readings.
     
    Refillable
    The HI1048B is a refillable probe. Since it is a double junction pH electrode, the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode fill solutions.
     
    Glass Electrode Body
    The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature
    dependent. The faster the equilibrium the steadier the reference potential.
     
    BNC Connector
    The HI1048B has a BNC connector. This type of connector is universal in that it can be used on any pH meter that has a female BNC probe input. Other types of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.
    Single Junction Versus Double Junction pH Electrodes
     
    Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.
     
    Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.
    • Able to measure samples 0-80C
    • Glass body, refillable sleeve junction
    • pH electrode with a BNC connector and a 0.5m cable
    • Clogging Prevention System (CPS) Technology
    • Refillable Electrode
    • Double Junction Design
     
     

     

     


     

    Hanna pH Electrode with Clogging Prevention System (CPS™) and BNC Connector (0.5m Cable) (Replacement electrode for HI84502-01) (Hanna# HI1048B/50)

      Product form

      SKU: MT693Z

      $264.00

      Calculating shipping time...
      Shipping
      Free Shipping*
      Shipping
      Paid Shipping
      Drop Ship
      Drop Ship
      Discount Exclusion
      Discount Exclusion
      Freight
      Freight Only
      Pre-book
      Pre Order

        Prop 65 Warning WARNING : This product can expose you to chemicals including Tetrafluoroethylene, which is/are known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov.

        Description

        The HI1048B is a glass body, refillable, sleeve junction pH electrode with a BNC connector. This electrode features a double junction reference, Hanna's Clogging Prevention System (CPS) technology and spherical glass sensing bulb made with general purpose glass. This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode.
        • Clogging Prevention System (CPS™) Technology
        • Refillable Electrode
        • Double Junction Design
        Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.
         
        The HI1048B uses general purpose (GP) glass, spherical bulb, glass body, sleeve junction with CPS™ technology, double junction and is refillable with 3.5M KCl, making it ideal for wine must, juice, and other samples with a high solids content.
         
        General Purpose Glass Formulation
        General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25°C and is suited for measuring the pH of samples that are at ambient temperatures. The HI1048B is suitable to use with samples that measure from 0 to 80°C.
         
        Spherical Glass Tip
        The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability.
         
        CPS Sleeve Junction
        Clogging Prevention System (CPS) technology is an innovation in for the improvement of pH measurements in samples that have a high solids content. Conventional pH electrodes use ceramic junctions that can clog quickly when used in samples that have a high solids content such as wine must or juice. When the junction is clogged, the electrode does not function. CPS technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows the proper flow of the liquid, while the PTFE sleeve repels solids. As a result, pH electrodes with CPS technology take up to 20 times longer to be fouled as compared to conventional electrodes.
         
        Double Junction Reference
        A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or for samples that contain sulfides that can cause the silver to precipitates and clog the junction. The clogging of the junction will result in drifty and erratic readings.
         
        Refillable
        The HI1048B is a refillable probe. Since it is a double junction pH electrode, the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode fill solutions.
         
        Glass Electrode Body
        The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature
        dependent. The faster the equilibrium the steadier the reference potential.
         
        BNC Connector
        The HI1048B has a BNC connector. This type of connector is universal in that it can be used on any pH meter that has a female BNC probe input. Other types of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.
        Single Junction Versus Double Junction pH Electrodes
         
        Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.
         
        Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.
        • Able to measure samples 0-80C
        • Glass body, refillable sleeve junction
        • pH electrode with a BNC connector and a 0.5m cable
        • Clogging Prevention System (CPS) Technology
        • Refillable Electrode
        • Double Junction Design
         
         

         

         


         

        Important Warnings & Shipping Info +
        Shipping Icon
        Free Shipping: Fast & Free Shipping over $79
        Shipping Icon
        Shipping Rates Apply: Bulk items like grain, bottles, and malt are excluded from our free shipping promotion due to their weight, and often dropship items. Standard shipping rates apply and are calculated at checkout based on your location and order size.
        Drop Ship Icon
        Drop Ship: This product will ship directly from the supplier. Delivery may take 1-4 weeks depending on the vendor.
        Discount Exclusion Icon
        Discount Exclusion: This item is not eligible for sitewide price reductions or percentage discounts. Learn more.
        Freight Icon
        Freight Shipping: This item ships freight only.
        Pre-book Icon
        Pre Order: This item is available for Pre-Order. Full payment is required to reserve stock.
        Shipping Weight: 0.1 lb
        • 5 stars: 542 (71%)
        • 4 stars: 174 (23%)
        • 3 stars: 50 (7%)
        • 2 stars: 0 (0%)
        • 1 star: 1 (0%)
        G
        George Dennis Hockaday

        I got my kit from CellarScience as they always have great products. First off the test works great. But I do have some issues. They give you enough acid standard to run hundreds of test. They are very generous with paper and capillary tubes. My lower rating is due to the jar and the developer. The 4 oz bottle of developer will not nearly do the 25 pages of test. The jar has a ridge in the bottom. When you set the paper in it makes it tilt over and it also raises the paper on an angle which makes it barely touch the liquid. I would have thought that the kit would contain enough developer to use up the stack of paper. The pix shows an 8 oz bottle of developer. Perhaps a mistake?

        D
        David
        Satisfied

        Probe received in good order and was properly hydrated. Kegland and MoreBeer are the two best brands in homebrewing.

        C
        Candler
        My 1st Refractometer

        This is a neat device. Some things that may assist you are: 1.) first test it with distilled water and adjust accordingly via the circular piece on the bottom. You can use a flat head or your finger. Note the entire plastic movable flap must be covered in liquid to produce an accurate reading. 2.) refractometers should be used to measure the sugars in the mash and after the boil. Note this device measures accurately at 20 Celsius (68 Fahrenheit) so if you take a reading below or higher than 20 Celsius then search for a refractometer correction chart in Google to aid in adjusting for the temperature difference. 3.) this refractometer is not designed to read final gravity due to alcohol being more dense which makes the final gravity appear lower. I've heard of some that do read alcohol but some people say they are not accurate (off by 10% abv or so). The cheapest and sure way is to have a hydrometer and a hydrometer jar to measure the final gravity. Use the refractometer for everything else because it's faster and waste less wort. 4.) this refractometer is designed to be used with natural light so the better the light the clearer the lines of your reading.

        C
        Christopher
        well made

        well made hydrometer in a comfortable and tight case.

        M
        Marco
        absolutely needed for Brewzilla Gen4 but.....

        absolutely needed for Brewzilla Gen4 because without it you're literally flying blind as to what the temperature of the actual mash is. The integrated temp probe at the bottom of the brewery can reach and overshoot target temps much faster than the mash temp. The problem is that it is cheaply made like much of Kegland's electronic devices and incredibly there is no way to calibrate it. First one I bought (from another vendor) went way out of calibration just before the warranty. The one I bought here died after just a month and two uses.

        M
        Mick
        Wonderful to use but there are Hidden Charges

        I've been very impressed with my unit and couldn't go back to my old methods of measuring SG. I am however very annoyed at the hidden charges for storing information within the app. After 10 batches a fee of $39.99 is now required that is scandalous. Nowhere was this information visible when I purchased my init from MoreBeer. I guess Anton Par assumes that once you've brewed 10 bathes you now qualify as "Pro". This is an expensive quality instrument please don't cheat us once we've purchased it.

        C
        Canh
        Works just like it did 10 yrs ago when I bought it

        I've had this going on 10 years now. Works reliably and as intended. The materials used have not shown any sign of degradation and still work as good as it did through hundreds of brews. I use this as my after boil chill loop to make sure wort is good temp before sending it to the fermenter. - magicalpancake

        M
        Michael R
        Seems to work ok.

        The unit had to be calibrated right out of the box. No big deal I had bought ph calibrating solution. I tried the 7.0 solution and the meter read 6.8. I adjusted it like the directions said. I then tried it in test solution that was 4.0 and it was spot on. The reason for the 3 stars is when I opened the battery compartment to pull out the insulating strip the battery in the center was exploded. I took them out and a metal clip fell out too. I got that put back in and got some fresh batteries. It takes 3 batteries and there is no way they fit. All 3 fit in the compartment but there was so much space they could not begin to make contact. I had to jam a wad of aluminum foil into the space at the end of the row of batteries. The meter seems to work ok. But gee I really didn't think economy meant poor quality. It works but I really do not recommend this product.

        N
        NickC
        This is the best thing on the market

        Very easy to use all you need to get precise information on OG final gravity ABV of the final product. When I got my hands on this equipment my life became much easier and happier! P.S. very quick replies from customers service Highly recommend for brewers

        D
        Daniel W
        While pricey it's worth it.

        I watched all of the videos and the speed and accuracy of this device is mind blowing. The smartref opens a lot of doors from beer to meed to fruited beer to checking your glycol concentration on your glycol chiller or more... they have multiple apps depending on the use and still curious to try some of the other features. It takes about two seconds to give you a number and a temp. Heartily recommend this bad boy

        M
        Mike
        Can't answer my own questions on MB so....

        I wrote a series of questions to Anton Paar after submitting them to MoreBeer. It won't let me post a response to my own question so I hope this helps....: ------- 1)Just to be clear: You're saying I can obtain an accurate (within half a percent) ABV reading without any kind of Original Gravity record? Yes the combination of EasyDens with SmartRef allow the measurement of density and refractive index. By knowing these two measurement values it is possible to calculate the ABV with an accuracy of 0.5 % v/v. 2) If I'm measuring fruited / adjunct beers is the ABV% reading still reliable and in the same 0.5% margin of error? Unfortunately it does not work if you add fruits. In this case there is additional sugar which influences the measurement and the result will be incorrect. 3) On the 'SmartRef' individual item page on MoreBeer they have this statement "EasyDens gives accurate readings at any point during fermentation without the need for an original reading." Does this mean I can pull ABV without an OG measurement with just EasyDens (rather than as part of the EasyDens-SmartRef combo) No this is not correct. You cannot measure ABV of beer using only EasyDens. If you are just using EasyDens for alcohol calculation you will need OG and FG. But EasyDens does the calculation of the estimated alcohol content fully automatically. 4) On the EasyDens individual page MoreBeer has this statement: Features Free: Basic features and all measurement units Premium features: Free for one year". Given that Is ABV-without-OG considered a measurement unit or a premium feature? You can perform 10 ABV measurements per month for free if you need more ABV measurements per month you will need the premium version. 4.a) Eitherway what are the costs of the premium features of the apps and what are those premium features? Information about in-app purchases can be found in your Apple App Store or Google Play Store. There are several premium features like Temperature coefficient free selectable Higher resolution for most measurement values Unlimited batches in the app Unlimited ABV measurements two different units free selectable on the display I hope this information is helpful to you. If you have any further requests do not hesitate to contact me. All the best Esther Support Team

        I
        Irving
        Good product

        Try to keep it upright since the cap is not really tight it may leak and will crystalize on the threads

        I
        Irving
        Usefull

        I like this device pretty accurate and easy to use and clean the drawback is that it needs an app to give you a reading and it will try to charge you extra for "better" accuracy

        M
        Matt
        Right Price Accurate Take care of it.

        I bought this without knowing anything about ph meters and was happy Morebeer recommended the storage solution. As many have said mine came a bit dry and had crystals in the cap. Kind of hard to avoid if you ask me but I re-hydrated with the storage solution and then did a 3 point calibration with no problem. Immediately tested distilled water and got the expected ph and used on my first brew day since I got it and it worked well. I'm not certain the typical protocol but I found taking a small sample of the mash or boiling wort into a glass jar (not a large sample) and letting it cool just slightly was better than dunking it in boiling wort or hot mash. I'm pretty sure if you take care of this keep some storage solution in the sealed cap it will last as much as you need. I did notice that I got the very best results especially during calibration if you religiously rinse the probe with distilled water between each test.

        L
        Leon Thomas
        Works Great!

        Works great. I've had my SC-300 since 2017. The SO2 measurements were always questionable. With this new probe they are easy repeatable and believable. I probably should have returned the original probe for replacement. The new probe is great!!

        J
        James M.
        Hydrometer with temp adjustment

        Easy temperature adjustment in this device. No need to make actual temperature adjustment for accurate SP Gravity reading. No looking up in a chart for correct adjustment.

        M
        Mark
        This is a wine saver

        This Tester was recommended by Smart Winemaking and The Home Winemaking Channel and it has been a wine saver Excellent results.

        C
        Contractor
        Hydrometer

        Nerve fails three readings based on what you're producing ie Beer Wine.

        J
        John
        Small

        This is one small thermometer.

        A
        Adam
        Easy to use

        This has made checking gravity incredibly simple.

        A
        Addisson

        Works just as it should. Love the thermometer to adjust the reading

        J
        Jerold J
        Best in Class

        Instructions easy to follow and super easy to use making SO2 analysis and additions a breeze!

        A
        Aristaeus Craft Brewing
        Expensive Must Have

        I was looking to start canning with small line I recently purchased and this device was must have. It is imperative to have the correct volume CO2 when packaging. Quality beer and packaging separates you from the rest of the herd.

        L
        Leonardo Arturo Febo Romero Y
        A "must have" for home brewers which don't want to miss any detail on the preparation of a good r...

        I like it very much. Is like going back to chemestry sessions from high school. Pills and accesories very well marked and with safety use precautions. The case is also very well fitted.

        G
        Garrett R.
        Works great

        It is a bit expensive but works great. The small samples and quick reading is awesome. No more constantly spinning a hydrometer or questioning rather or not it is accurate.

        P
        Peter
        Great!

        Costly but definitely worth the confidence and efficiency in my gravity readings.

        T
        Timothy

        Overall I think this is a great product. I am still working on really calibrating as the calibration in distilled water still leaves my higher gravity readings several points lower than my actual hydrometer when I compare the two. For monitoring the actual fermentation and temperature however this has been a very handy tool. It's great to know when your beer hits your FG!